Vacuum pump accessories protect the pump, vacuum system, and process from contamination, and reduce exhaust emissions. Oil mist traps collect oil mist from the pump exhaust. Silencers reduce exhaust noise. Water-cooled baffles and cold traps reduce backstreaming into the vacuum chamber. Dust filters and particle traps protect the pump inlet. Baking jackets and heaters maintain pump-body temperature in reactive-gas applications.

Oil Mist Traps

Oil mist traps are installed on the exhaust connection of oil rotary vacuum pumps to collect oil mist before it enters the exhaust line or the laboratory atmosphere. Select the trap size to match the pump exhaust port. Replace the trap element when the drain level indicates saturation or when visible mist breakthrough occurs.

Part NumberModelSpecification
210006804600TMX-1For PVD-180 w/adaptor. English
210009003600TMX-1For PVD-360, D-240DK, VD151. w/adaptor. English
210009003500TMX-1For D-330K-D-650K. English
210006441700TMX-1H He tightFor PVD-180, w/adapter and RF-11. English
210006441800TMX-1H He tightFor PVD-360/D-240DK, w/adapter and RF-11. English
210006441600TMX-1H He tightFor D-330K/DK. 650K/DK, w/RF-11. English
210009003700TMX-2For D-950, English
210006441900TMX-2H He tightFor D-950K/DK, w/RF-12. English
210009002800TM-2For VD601/901, w/adaptor. Umbrella model, English
210009002600TM-2For PKS-016 Umbrella model, English
210006805000TM-2 with pressure gaugeFor VD601/901, w/adaptor. Umbrella model, English
210006805100TM-2 with pressure gaugeFor PKS-016 Umbrella model, English
210009002700TM-2(F)For VD601/901, w/adaptor. Flange model, English
210009002500TM-2(F)For PKS-016 Flange model, English
210006805300TM-2(F) with pressure gaugeFor VD601/901, w/adaptor. Flange model, English
210006805200TM-2(F) with pressure gaugeFor PKS-016 Flange model, English
210009002400TM-3For VS1501 Umbrella model, English
210009002300TM-3For PKS-030 Umbrella model, English
210006805400TM-3 with pressure gaugeVS1501 Umbrella model, English
210006805500TM-3 with pressure gaugeFor PKS-030 Umbrella model, English
210009002200TM-3(F)For VS1501 Flange model, English
210009002100TM-3(F)For PKS-030 Flange model, English
210006805600TM-3(F) with pressure gaugeFor VS1501 Flange model, English
210006805700TM-3(F) with pressure gaugeFor PKS-030 Flange model, English
210009002000TM-4For VS2401 Umbrella model, English
210009001900TM-4For PKS-070 Umbrella model, English
210006805800TM-4 with pressure gaugeFor VS2401 Umbrella model, English
210006805900TM-4 with pressure gaugeFor PKS-070 Umbrella model, English
210009001800TM-4(F)For VS2401 Flange model, English
210009001700TM-4(F)For PKS-070 Flange model, English
210006806000TM-4(F) with pressure gaugeFor VS2401 Flange model, English
210006806100TM-4(F) with pressure gaugeFor PKS-070 Flange model, English
210006806200TM-4SFor VS2401, high load, English
210006806300TM-4SFor PKS-070, high load, English
210006806400TM-4S with pressure gaugeFor VS2401, high load, English
210006806500TM-4S with pressure gaugeFor PKS-070, high load, English
250004201100TM201English, w/bolt&nut, incl. case fee
250004201200TM401English, w/bolt&nut, incl. case fee

Silencers

Silencers are installed on the exhaust of dry or oil-free pumps to reduce acoustic emissions. Select the silencer to match the pump exhaust port size and flow rate.

Part NumberModelSpecification
210006422400RS-01for:LR60, 90, 300, 600, 1200, / CR16, 30, 60, 300, / GR60, 90, Silencer only, Instruction Manual English
210006424700RS-01-Afor:LR60, 90, 300(CE), / CR60, / GR60, 90, w/kit_A, Instruction Manual English
210006424900RS-01-Bfor:LR60CE, 90CE, 600(CE), 1200(CE), w/kit_B, Instruction Manual English
210006825900RS-01-Cfor:CR300, w/kit_C, Instruction Manual English
210006867100RS-01-Dfor:CR16, 30, w/kit_D, English instruction manual
210006422600RS-02for:LR180, 1800, Silencer only, Instruction Manual English
210006425100RS-02-Afor:LR180, w/A kit, Instruction Manual English
210006425300RS-02-Bfor:LR180CE, 1800(CE), w/B kit, Instruction Manual English
210006802600RS-02-Cfor:GR180, PMB1200+GR180, w/C kit, English instruction
210006422800RS-03for:LR420, 421, 3600, 3601, Silencer only, Instruction Manual English
210006425500RS-03-Afor:LR420, 421, w/kit_A, Instruction Manual English
210006425700RS-03-Bfor 3600, 3601, w/kit_B, Instruction Manual English
210006879600EFS-11-NW25/2/2516for CR16, 30
210006826300EFS-19-NW40/1for CR60, 300

Water-Cooled Baffles and Water-Cooled Traps

Water-cooled baffles and traps are installed between diffusion pumps (or other high-vacuum pumps) and the vacuum chamber. They condense pump-fluid vapour and reduce backstreaming into the process volume. Connect the cooling-water supply before operating the pump — the baffle or trap does not operate correctly without cooling flow.

Part NumberModelSpecification
210004202800BW-02Mild Steel, for PBL-02
210004202900BW-2 1/2Mild Steel, for U-250, F-250
210004203000BW-04BStainless Steel, for ULK-04A, PBL-04
210004203100BW-04Bw/adaptor
210004203200BW-06BStainless Steel, for ULK-06A, PBL-06
210004203300BW-06Bw/adaptor
210004203400BW-10Mild Steel, for ULK-10A, PBL-10
210004203500BW-14Mild Steel, for ULK-14A, PBL-14
210004960000BW-20mild steel For PBL-20
210004960100BW-22mild steel For PFL-22
210004960200BW-36mild steel For PFL-36
210004204900WT-25Stainless steel
210004205000WT-50Stainless steel
210004205100WT-80Stainless steel
210004205200WT-100Stainless steel
210004204500WT-25Soft Steel
210004204600WT-50Soft Steel
210004204700WT-80Soft Steel
210004204800WT-100Soft Steel

Cold Traps

Cold traps use a cryogenic fluid (liquid nitrogen or refrigerant) to condense water vapour and organic molecules before they reach the pump. Cold traps are essential in processes where condensable vapours must be prevented from entering the pump oil or process chamber.

Part NumberModelSpecification
210004205300CT-25Stainless steel
210004205400CT-40Stainless steel
210004205500CT-50Stainless steel
210004205600CT-80Stainless steel
210004205700CT-100Stainless steel

Dust Filters, Particle Traps, Oil Traps, and Heating Accessories

Dust filters and particle traps protect the pump inlet from process-side contamination. Baking jackets and heaters maintain pump body temperature in corrosive or condensable gas applications.

Part NumberModelSpecification
210004205800OT-50Stainless steel
210004205900OT-80Stainless steel
210004206000OT-100Stainless steel
210004203800TRO-50
210004203900TRO-80
210004204000TRO-100
210005119000DS-20SUS + GBB
210004206100DS-25SUS + GBB
210004206200DS-40SUS + GBB
210004206300DS-50SUS + GBB
210004206400DS-2SUS + GBB
210004206500DS-3SUS + GBB
210004206600DS-4SUS + GBB
200009146700For UTM300BAC100V, 200W for ICF Flange type
200009146800For UTM300BAC230V, 200W for ICF Flange type
200009461200For UTM70BAC100V、65W for ICF Flange type
200009461300For UTM70BAC230V、65W for ICF Flange type
210004743400For UTM-350/480FW(H), AC200V
210004743500For UTM-800/1001FW(H), AC200V
210004554700For UTM-1400FW, AC200V
210004554800For UTM-2300FW, AC200V
210004554900For UTM-3301FW/3002FH, AC200V
200006950700CGM-JH01For CGM
200006950800CGM-JH02for CGM-QIP
200006950900BGM-JH01For BGM
200007245500HGM-JH01for HGM-202/302

Service Enquiry

Email: mail@ulvacheliot.com
Provide: accessory model, part number, pump model it is fitted to, and service or replacement requirement.

Independent HELIOT Equipment Service

Independent third-party maintenance, commissioning and training provider for ULVAC HELIOT helium mass spectrometer leak detectors. We are not the manufacturer and do not sell new ULVAC equipment. Worldwide on-site support.

mail@ulvacheliot.com


Independent service provider notice: This website is operated by an independent, third-party technical service organisation. We provide on-site and remote maintenance, commissioning, repair and training services for existing ULVAC HELIOT equipment already owned or procured by our customers. We are not ULVAC Corporation, not a subsidiary, dealer, distributor, or authorised representative of ULVAC Corporation, and we do not sell new ULVAC equipment. ULVAC® and HELIOT® are registered trademarks of ULVAC Corporation (Japan), used here solely in a descriptive, nominative sense to identify the equipment we service. | Full Trademark Disclaimer | Contact